CO1 - Olympus Fluoview 1000

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 9: Line 9:
 
| building            = MPI-CBG
 
| building            = MPI-CBG
 
| room                = 038A
 
| room                = 038A
| description          = Single photon point scanning [[Olympus FV1000]] [[confocal]] microscope with three confocal PMTs and transmitted light detector. Inverted configuration with additional scanner and pulsed laser
+
| description          = Single photon point scanning [[Olympus FV1000]] [[confocal]] microscope with four confocal PMTs and one transmitted light detector. Inverted configuration with additional scanner and pulsed picosecond laser
 
| applications        = ablation experiments
 
| applications        = ablation experiments
 
| microscope          = inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC  
 
| microscope          = inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC  
 
| objectives          = 10x/0.4 UPlanApo<br>20x/0.7 UPlanApo<br>40x/0.85 UPlanApo<br>60x/1.4 Oil PlanApo<br>60x/1.2 W UPlanApo
 
| objectives          = 10x/0.4 UPlanApo<br>20x/0.7 UPlanApo<br>40x/0.85 UPlanApo<br>60x/1.4 Oil PlanApo<br>60x/1.2 W UPlanApo
| illumination        = Halogen<br>HBO<br>405nm diode laser<br>458, 488, 515, 633 nm HeNe laser<br>561 nm Diode laser<br>
+
| illumination        = Halogen<br>HBO<br>405nm diode laser<br>458, 488, 515 ArgonLaser<br>633 nm HeNe laser<br>561 nm Diode laser<br>
| detection            = point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral sliders and emission filters for detection range selection, pinhole for each detector
+
| detection            = point scanner, 4 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral sliders and emission filters for detection range selection, pinhole for each detector
 
| reflectors          =  
 
| reflectors          =  
| features            = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, Kalman [[averaging]], summarizing, scan zoom and rotation
+
| features            = simultaneous imaging using a 405nm picosecond  Diode laser (PicoQuant), sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, Kalman [[averaging]], summarizing, scan zoom and rotation
 
| incubation          = -
 
| incubation          = -
 
| link1                = [http://spreadsheets.google.com/pub?key=pFACvabR4mSmt7IA5ZOd9Yw LPM]
 
| link1                = [http://spreadsheets.google.com/pub?key=pFACvabR4mSmt7IA5ZOd9Yw LPM]
 
| link2                = -
 
| link2                = -
 
}}
 
}}

Revision as of 14:31, 27 August 2008

Suitable for ablation experiments.
MPI09.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MPI-CBG LMF (MPI-CBG, 038A)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope , inverted stand, inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
objectives
illumination
detection point scanner, 4 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral sliders and emission filters for detection range selection, pinhole for each detector
reflectors
features [[features::simultaneous imaging using a 405nm picosecond Diode laser (PicoQuant), sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, Kalman averaging, summarizing, scan zoom and rotation]]
software
incubation -
links
  • [ manual]
  • [LPM laser power values]
  • [- beam path]
  • [ advanced system check]
inv.nr.



[[Category:{{{type}}}]]