CO1 - Olympus Fluoview 1000
From BioDIP
(Difference between revisions)
Line 15: | Line 15: | ||
| illumination = Halogen<br>HBO<br>405nm diode laser<br>458, 488, 515 ArgonLaser<br>633 nm HeNe laser<br>561 nm Diode laser<br> | | illumination = Halogen<br>HBO<br>405nm diode laser<br>458, 488, 515 ArgonLaser<br>633 nm HeNe laser<br>561 nm Diode laser<br> | ||
| detection = point scanner, 4 confocal [http://en.wikipedia.org/wiki/Photomultiplier PMTs], two independent spectral detection channels, each one configured with a diffraction grating and variable slit for high-resolution wavelength separation and high-speed bandwidth selection, two filter based detection channels, T-PMT, [http://spreadsheets.google.com/pub?key=pMZJXCgd5HNt00W82g1G1TA dichromatic mirrors for excitation/emission splitting], one pinhole | | detection = point scanner, 4 confocal [http://en.wikipedia.org/wiki/Photomultiplier PMTs], two independent spectral detection channels, each one configured with a diffraction grating and variable slit for high-resolution wavelength separation and high-speed bandwidth selection, two filter based detection channels, T-PMT, [http://spreadsheets.google.com/pub?key=pMZJXCgd5HNt00W82g1G1TA dichromatic mirrors for excitation/emission splitting], one pinhole | ||
− | | reflectors = Filter | + | | reflectors = Filter Cube 1. [http://www.olympusamerica.com/seg_section/uis2/seg_uis2_mr_umwu2.asp U-MWU2]. BP330-385 BA420 DM400 |
Filter Cube 2. [http://www.olympusamerica.com/seg_section/uis2/seg_uis2_mr_umwb2.asp U-MWB2]. BP460-490 BA520IF (High performance interference filter) DM500<br> | Filter Cube 2. [http://www.olympusamerica.com/seg_section/uis2/seg_uis2_mr_umwb2.asp U-MWB2]. BP460-490 BA520IF (High performance interference filter) DM500<br> | ||
Filter Cube 3. [http://www.olympusamerica.com/seg_section/uis2/seg_uis2_mr_umwg2.asp U-MWG2]. BP510-550 BA590 DM570 | Filter Cube 3. [http://www.olympusamerica.com/seg_section/uis2/seg_uis2_mr_umwg2.asp U-MWG2]. BP510-550 BA590 DM570 |
Revision as of 16:36, 29 August 2008
Directions
[[image:|150px|text-bottom|right]]
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | , inverted stand, inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
objectives |
| ||
illumination |
| ||
detection | [[detection::point scanner, 4 confocal PMTs, two independent spectral detection channels, each one configured with a diffraction grating and variable slit for high-resolution wavelength separation and high-speed bandwidth selection, two filter based detection channels, T-PMT, dichromatic mirrors for excitation/emission splitting, one pinhole]] | ||
reflectors | [[reflectors::Filter Cube 1. U-MWU2. BP330-385 BA420 DM400
Filter Cube 2. U-MWB2. BP460-490 BA520IF (High performance interference filter) DM500 | ||
features | [[features::Two independent and fully synchronized laser scanners for simultaneous laser stimulation and observation, laser stimulation can be performed using the imaging laser or a 405nm picosecond Diode laser (PicoQuant), sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, Kalman averaging, summarizing, scan zoom and rotation]] | ||
software | |||
incubation | - | ||
links |
| ||
inv.nr. |
[[Category:{{{type}}}]]