|description=Our inverted ApoTome2 Microscope with hardware autofocus, colour and monochrome cameras is designed for routine work on fixed sample. Optical sectioning can be obtained on fixed samples by the use of the ApoTome2 slider.
 
|description=Our inverted ApoTome2 Microscope with hardware autofocus, colour and monochrome cameras is designed for routine work on fixed sample. Optical sectioning can be obtained on fixed samples by the use of the ApoTome2 slider.
 
|applications=multichannel fluorescence, 3-D, time-lapse, tile scan, multiple points, hardware autofocus
 
|applications=multichannel fluorescence, 3-D, time-lapse, tile scan, multiple points, hardware autofocus
 +
|image=ApoTome2, inverse, CRTD.jpg
 
|stand-name=Zeiss - Axio Observer
 
|stand-name=Zeiss - Axio Observer
 
|stand=Inverted
 
|stand=Inverted

Revision as of 15:07, 10 February 2012

Suitable for multichannel fluorescence, 3-D, time-lapse, tile scan, multiple points, hardware autofocus.
ApoTome2, inverse, CRTD.jpg


Directions

CRTD logo.PNG
Imaging@Biotec.jpg Imaging@Biotec"Imaging@Biotec" is not in the list of possible values (DZNE - Imaging Platform, EM- and Histo-Facility CRTD / BIOTEC, Image Processing@BIOTEC, Imaging@BIOTEC/CRTD, MPI-CBG LMF, MPI-CBG LMF - Quantitative Image Analysis Unit, MPI-CBG TDS, MTZ Imaging, MPI-CBG EM, BioDIP) for this property. (CRTD, -1.124)

Booking

https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c

Details

microscope Zeiss - Axio Observer, Inverted stand, automatic XY stage, motorized z-stage, fluorescence, transmitted light with manual DIC (Senarmont), b/w epifluorescence acquisition, Optical Sectioning (ApoTome2)
objectives
Zeiss EC Plan-Neofluar 5x 0.16 Ph1
Zeiss EC Plan-Neofluar 10x 0.3 Ph1
Zeiss C-Apochromat 10x 0.45 W
Zeiss Plan-Apochromat 20x 0.8 Ph2
Zeiss C-Apochromat 40x 1.2 W
illumination
Fluorescence (HBO)
Fluorescence (Metal Halide, HXP, 120W)
Fluorescence (LED)
detection Axiocam HRc (1388*1040, 6,45*6,45µm pixel) - color
reflectors FS 49: EX BP 347/55; BS 395; EM BP 445/50 (Dapi)

FS 38HE: EX BP 471/40 (HE); BS 495 (HE); EM BP 495-545 (HE); (GFP)
FS 43HE: EX BP 550/25 (HE); BS 570 (HE); EM 605/70 (HE); (Cy3)
FS Cy5: (Cy5)
FS F56-422: EX -; BS 500-555 & BP 615-675; EM BP 525/60 & BP 650/80; (GFP-DsRed)
FS Analysator for DIC and Transmission

features -
software -
incubation Not available
links
  • [ manual]
  • [ laser power values]
  • [ beam path]
  • [ advanced system check]
inv.nr. 70836