ApoTome2, inverse, CRTD
From BioDIP
(Difference between revisions)
(Created page with '{{Equipment |system-number=BIO04 |system-name=ApoTome2, CRTD |type=Microscope |category=Wide-Field |facility=Imaging@Biotec |building=CRTD |room=-1.124 |Facility-logo=Imaging@Bio...') |
|||
(23 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{Equipment | {{Equipment | ||
|system-number=BIO04 | |system-number=BIO04 | ||
− | |system-name=ApoTome2, CRTD | + | |system-name=ApoTome2, inverse, CRTD |
|type=Microscope | |type=Microscope | ||
− | |category= | + | |category=Structured Illumination |
− | |facility=Imaging@ | + | |facility=Imaging@BIOTEC/CRTD |
|building=CRTD | |building=CRTD | ||
|room=-1.124 | |room=-1.124 | ||
|Facility-logo=Imaging@Biotec.jpg | |Facility-logo=Imaging@Biotec.jpg | ||
|Institute-logo=CRTD logo.PNG | |Institute-logo=CRTD logo.PNG | ||
− | |description=Our inverted ApoTome2 Microscope is designed for routine work on fixed sample. Optical sectioning can be obtained on fixed samples by the use of the ApoTome2 slider. | + | |description=Our inverted ApoTome2 Microscope with hardware autofocus, colour and monochrome cameras is designed for routine work on fixed sample. Optical sectioning can be obtained on fixed samples by the use of the ApoTome2 slider. |
− | |applications=- | + | |applications=multichannel fluorescence, 3-D, time-lapse, tile scan, multiple points, hardware autofocus |
− | |stand-name=Zeiss - Axio Observer | + | |image=ApoTome2, inverse, CRTD.jpg |
+ | |stand-name=Zeiss - Axio Observer.Z1 | ||
|stand=Inverted | |stand=Inverted | ||
− | |microscope=automatic XY stage, motorized z-stage, fluorescence, transmitted light with manual DIC (Senarmont), b/w epifluorescence acquisition, Optical Sectioning (ApoTome2) | + | |microscope=automatic XY stage, motorized z-stage, fluorescence, transmitted light with manual DIC (Senarmont), b/w epifluorescence acquisition, Optical Sectioning (ApoTome2), Mosaic (tile scans) |
− | + | ||
|obj2=Zeiss EC Plan-Neofluar 10x 0.3 Ph1 | |obj2=Zeiss EC Plan-Neofluar 10x 0.3 Ph1 | ||
− | | | + | |obj4=Zeiss LD Achroplan 20x 0.4 Ph2 |
− | | | + | |obj5=Zeiss EC Plan-Neofluar 40x 0.6 Ph2 |
− | | | + | |obj7=Zeiss C-Apochromat 63x 1.2 W |
− | |detection=- | + | |obj8=Zeiss EC Plan Neofluar 2.5x 0.075 |
− | |reflectors=- | + | |obj9=Zeiss Plan-Apochromat 20x 0.8 |
+ | |ill1=Fluorescence (LED, 470nm) | ||
+ | |ill2=Fluorescence (LED, 590nm) | ||
+ | |ill3=Fluorescence (Metal Halide, HXP, 120W) | ||
+ | |ill4=Transmitted Light (Halogen) | ||
+ | |detection=Axiocam HRc (1388*1040, 6,45*6,45µm pixel) - color <br> | ||
+ | Axiocam MRm (1388*1040, 6,45*6,45µm pixel) - b/w <br> | ||
+ | tube lens 1x and 1.6x | ||
+ | |reflectors=FS 49: EX BP 347/55; BS 395; EM BP 445/50 (Dapi)<br> | ||
+ | FS 38HE: EX BP 471/40 (HE); BS 495 (HE); EM BP 495-545 (HE); (GFP)<br> | ||
+ | FS 43HE: EX BP 550/25 (HE); BS 570 (HE); EM 605/70 (HE); (Cy3)<br> | ||
+ | FS Cy5: EX BP 662-738; BS 660; EM BP 700/75; (Cy5)<br> | ||
+ | FS F56-422: EX BP 474/23 & BP 585/29; BS 495-555 & BP 610-690; EM BP 525/55 & BP 645/60; (GFP-DsRed)<br> | ||
+ | FS Analysator for DIC and Transmission | ||
|features=- | |features=- | ||
− | |software= | + | |software=32 bit: AxioVision |
+ | 64 bit: Win7 ZEN blue 2012 | ||
|incubation=Not available | |incubation=Not available | ||
− | |inv= | + | |inv=70836 |
}} | }} |
Latest revision as of 13:36, 17 October 2014
[edit] Directions
[edit] Booking
https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c
[edit] Details
microscope | Zeiss - Axio Observer.Z1, Inverted stand, automatic XY stage, motorized z-stage, fluorescence, transmitted light with manual DIC (Senarmont), b/w epifluorescence acquisition, Optical Sectioning (ApoTome2), Mosaic (tile scans) | ||
objectives | |||
illumination | |||
detection | Axiocam HRc (1388*1040, 6,45*6,45µm pixel) - color Axiocam MRm (1388*1040, 6,45*6,45µm pixel) - b/w | ||
reflectors | FS 49: EX BP 347/55; BS 395; EM BP 445/50 (Dapi) FS 38HE: EX BP 471/40 (HE); BS 495 (HE); EM BP 495-545 (HE); (GFP) | ||
features | - | ||
software | 32 bit: AxioVision
64 bit: Win7 ZEN blue 2012"32 bit: AxioVision 64 bit: Win7 ZEN blue 2012" cannot be used as a page name in this wiki. | ||
incubation | Not available | ||
links |
| ||