ApoTome2, inverse, CRTD
From BioDIP
(Difference between revisions)
(14 intermediate revisions by 3 users not shown) | |||
Line 3: | Line 3: | ||
|system-name=ApoTome2, inverse, CRTD | |system-name=ApoTome2, inverse, CRTD | ||
|type=Microscope | |type=Microscope | ||
− | |category= | + | |category=Structured Illumination |
− | |facility=Imaging@ | + | |facility=Imaging@BIOTEC/CRTD |
|building=CRTD | |building=CRTD | ||
|room=-1.124 | |room=-1.124 | ||
Line 14: | Line 14: | ||
|stand-name=Zeiss - Axio Observer.Z1 | |stand-name=Zeiss - Axio Observer.Z1 | ||
|stand=Inverted | |stand=Inverted | ||
− | |microscope=automatic XY stage, motorized z-stage, fluorescence, transmitted light with manual DIC (Senarmont), b/w epifluorescence acquisition, Optical Sectioning (ApoTome2), | + | |microscope=automatic XY stage, motorized z-stage, fluorescence, transmitted light with manual DIC (Senarmont), b/w epifluorescence acquisition, Optical Sectioning (ApoTome2), Mosaic (tile scans) |
− | + | ||
|obj2=Zeiss EC Plan-Neofluar 10x 0.3 Ph1 | |obj2=Zeiss EC Plan-Neofluar 10x 0.3 Ph1 | ||
− | | | + | |obj4=Zeiss LD Achroplan 20x 0.4 Ph2 |
− | | | + | |obj5=Zeiss EC Plan-Neofluar 40x 0.6 Ph2 |
− | | | + | |obj7=Zeiss C-Apochromat 63x 1.2 W |
− | |ill1=Fluorescence (LED) | + | |obj8=Zeiss EC Plan Neofluar 2.5x 0.075 |
− | |ill2=Fluorescence (Metal Halide, HXP, 120W) | + | |obj9=Zeiss Plan-Apochromat 20x 0.8 |
+ | |ill1=Fluorescence (LED, 470nm) | ||
+ | |ill2=Fluorescence (LED, 590nm) | ||
+ | |ill3=Fluorescence (Metal Halide, HXP, 120W) | ||
+ | |ill4=Transmitted Light (Halogen) | ||
|detection=Axiocam HRc (1388*1040, 6,45*6,45µm pixel) - color <br> | |detection=Axiocam HRc (1388*1040, 6,45*6,45µm pixel) - color <br> | ||
− | Axiocam MRm (1388*1040, 6,45*6,45µm pixel) - b/w | + | Axiocam MRm (1388*1040, 6,45*6,45µm pixel) - b/w <br> |
+ | tube lens 1x and 1.6x | ||
|reflectors=FS 49: EX BP 347/55; BS 395; EM BP 445/50 (Dapi)<br> | |reflectors=FS 49: EX BP 347/55; BS 395; EM BP 445/50 (Dapi)<br> | ||
FS 38HE: EX BP 471/40 (HE); BS 495 (HE); EM BP 495-545 (HE); (GFP)<br> | FS 38HE: EX BP 471/40 (HE); BS 495 (HE); EM BP 495-545 (HE); (GFP)<br> | ||
FS 43HE: EX BP 550/25 (HE); BS 570 (HE); EM 605/70 (HE); (Cy3)<br> | FS 43HE: EX BP 550/25 (HE); BS 570 (HE); EM 605/70 (HE); (Cy3)<br> | ||
− | FS Cy5: (Cy5)<br> | + | FS Cy5: EX BP 662-738; BS 660; EM BP 700/75; (Cy5)<br> |
− | FS F56-422: EX | + | FS F56-422: EX BP 474/23 & BP 585/29; BS 495-555 & BP 610-690; EM BP 525/55 & BP 645/60; (GFP-DsRed)<br> |
FS Analysator for DIC and Transmission | FS Analysator for DIC and Transmission | ||
|features=- | |features=- | ||
− | |software= | + | |software=32 bit: AxioVision |
+ | 64 bit: Win7 ZEN blue 2012 | ||
|incubation=Not available | |incubation=Not available | ||
|inv=70836 | |inv=70836 | ||
}} | }} |
Latest revision as of 13:36, 17 October 2014
[edit] Directions
[edit] Booking
https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c
[edit] Details
microscope | Zeiss - Axio Observer.Z1, Inverted stand, automatic XY stage, motorized z-stage, fluorescence, transmitted light with manual DIC (Senarmont), b/w epifluorescence acquisition, Optical Sectioning (ApoTome2), Mosaic (tile scans) | ||
objectives | |||
illumination | |||
detection | Axiocam HRc (1388*1040, 6,45*6,45µm pixel) - color Axiocam MRm (1388*1040, 6,45*6,45µm pixel) - b/w | ||
reflectors | FS 49: EX BP 347/55; BS 395; EM BP 445/50 (Dapi) FS 38HE: EX BP 471/40 (HE); BS 495 (HE); EM BP 495-545 (HE); (GFP) | ||
features | - | ||
software | 32 bit: AxioVision
64 bit: Win7 ZEN blue 2012"32 bit: AxioVision 64 bit: Win7 ZEN blue 2012" cannot be used as a page name in this wiki. | ||
incubation | Not available | ||
links |
| ||
inv.nr. | 70836 |