H1 - DeltaVision OMX - pDV

From BioDIP
(Difference between revisions)
Jump to: navigation, search
 
(11 intermediate revisions by 5 users not shown)
Line 1: Line 1:
 
{{Equipment
 
{{Equipment
|system-number=MPI-H1-OMX
+
|system-number=MPI- H1
 
|system-name=DeltaVision OMX - pDV
 
|system-name=DeltaVision OMX - pDV
 
|type=Microscope
 
|type=Microscope
|category=Structured Illumination and Fast Widefield
+
|category=Superresolution
 
|facility=MPI-CBG LMF
 
|facility=MPI-CBG LMF
 
|building=MPI-CBG
 
|building=MPI-CBG
 
|room=036
 
|room=036
|Facility-logo=MPI-CBG LMF.jpg
+
|Facility-logo=MPI-CBG-Lmf-logo-big.png
|description=Applied Precision Inc Deltavision OMX v4 BLAZE: Live cell and fixed sample Structured Illumination Superresolution and very fast widefield. 4x sCMOS cameras, 405, 488, 568, 640 laser illumination widefield or structured 3D illumination. Also has its own personal DeltaVision widefield fluorescence microscope system with a stage that is registered with the OMX stage, for locating samples on the slide.
+
|Institute-logo=Logo MPI-CBG.jpg
|applications=super resolution of fixed and living samples down to 120 nm, and very fast widefield imaging.
+
|description=Applied Precision Inc Deltavision OMX v4 BLAZE: Live cell and fixed sample Structured Illumination Superresolution and very fast widefield. 4x sCMOS cameras, 405, 488, 568, 642 laser illumination widefield or structured 3D illumination. Also has its own personal DeltaVision widefield fluorescence microscope system with a stage that is registered with the OMX stage, for locating samples on the slide.
|image=H1-OMX.jpg
+
|applications=high resolution imaging of fixed and living samples down to 120 nm, and very fast widefield imaging.
 +
|image=H1-DeltaVision OMX-pDV.JPG
 
|stand-name=Applied Precision - OMX stand
 
|stand-name=Applied Precision - OMX stand
 
|stand=Inverted
 
|stand=Inverted
|microscope=nano precise XYZ stage, fast z peizo, , fast structured illumination OMX Blaze, fluorescence, transmitted light, DIC, plus IX71 for the pDV.
+
|microscope=nano precise XYZ stage, fast z piezo, , fast structured illumination OMX Blaze, fluorescence, transmitted light, DIC, plus IX71 for the pDV.
|obj1=Olympus UPlanSApo 100x 1.4 Oil
+
|obj1=Olympus UPlanSApochromat 100x 1.4 Oil
|obj2=Olympus UPlanSApo 10x 0.4
+
|obj2=Olympus UPlanSApochromat 10x 0.4
|obj3=Olympus PlanApo N 60x 1.42 Oil UIS2 inf/0.17/FN26.5 WD 0.15 mm
+
|obj3=Olympus PlanApochromatN 60x 1.42 Oil
 +
|obj4=Olympus PlanApochromatN 60x 1.42 Oil
 +
|obj5=Leica Achromatic 10x 0.25
 +
|obj6=Olympus PlanApochromatN 60x 1.42 Oil
 
|ill1=Transmitted Light (LED)
 
|ill1=Transmitted Light (LED)
 
|ill2=Laser Diode 405 nm
 
|ill2=Laser Diode 405 nm
Line 23: Line 27:
 
|ill5=Laser DPSS 640 nm
 
|ill5=Laser DPSS 640 nm
 
|detection=4x sCMOS cooled to 3oC. Simultaneous or sequential imaging.
 
|detection=4x sCMOS cooled to 3oC. Simultaneous or sequential imaging.
|reflectors="standard" set for fixed samples (also GFP, and some red proteins), OMX. See Docs at OMX. DAPI/FITC/TRITC/Cy5 - similar to Sedat Set.
+
|reflectors="standard" set for fixed samples (also GFP, and some red proteins), OMX. See Docs at OMX. DAPI/FITC/TRITC/Cy5 - similar to Sedat Set; second set for CFP/YFP/RFP
 
|features=fast 4 colour widefield. Super resolution by structured illumination in 3D, down to approx 120 nm resolution (2x the resolution of conventional light microscopy)
 
|features=fast 4 colour widefield. Super resolution by structured illumination in 3D, down to approx 120 nm resolution (2x the resolution of conventional light microscopy)
 
|software=API softworx and OMX software for driving the scope and super resolution reconstruction.
 
|software=API softworx and OMX software for driving the scope and super resolution reconstruction.
Line 30: Line 34:
 
|incubation=Stage incubator (T) + objective heater
 
|incubation=Stage incubator (T) + objective heater
 
|link0=[H1_OMX_Startup_and_Shutdown_manual]]
 
|link0=[H1_OMX_Startup_and_Shutdown_manual]]
 +
|link1=https://docs.google.com/spreadsheets/d/1azxZb1ZJFiPVnBz2gU-vSto4lPvairiyG9_LtmCSokU/pubhtml
 
|inv=MOZG040809900
 
|inv=MOZG040809900
 
|facility_image=Logo-lmf.jpg
 
|facility_image=Logo-lmf.jpg

Latest revision as of 15:23, 8 November 2016

Suitable for high resolution imaging of fixed and living samples down to 120 nm, and very fast widefield imaging..
H1-DeltaVision OMX-pDV.JPG


[edit] Directions

Logo MPI-CBG.jpg
MPI-CBG-Lmf-logo-big.pngMPI-CBG LMF (MPI-CBG, 036)

[edit] Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

[edit] Details

microscope Applied Precision - OMX stand, Inverted stand, nano precise XYZ stage, fast z piezo, , fast structured illumination OMX Blaze, fluorescence, transmitted light, DIC, plus IX71 for the pDV.
objectives
Olympus UPlanSApochromat 100x 1.4 Oil
Olympus UPlanSApochromat 10x 0.4
Olympus PlanApochromatN 60x 1.42 Oil
Olympus PlanApochromatN 60x 1.42 Oil
Leica Achromatic 10x 0.25
Olympus PlanApochromatN 60x 1.42 Oil
illumination
Transmitted Light (LED)
Laser Diode 405 nm
Laser DPSS 488 nm
Laser DPSS 561 nm
Laser DPSS 640 nm
detection 4x sCMOS cooled to 3oC. Simultaneous or sequential imaging.
reflectors "standard" set for fixed samples (also GFP, and some red proteins), OMX. See Docs at OMX. DAPI/FITC/TRITC/Cy5 - similar to Sedat Set; second set for CFP/YFP/RFP
features fast 4 colour widefield. Super resolution by structured illumination in 3D, down to approx 120 nm resolution (2x the resolution of conventional light microscopy)
software API softworx and OMX software for driving the scope and super resolution reconstruction.

OMX SI reconstruction linux box: centos 4, 10.1.145.31 personalDV linux centos5 box 10.1.145.32"API softworx and OMX software for driving the scope and super resolution reconstruction. OMX SI reconstruction linux box: centos 4, 10.1.145.31 personalDV linux centos5 box 10.1.145.32" cannot be used as a page name in this wiki.

incubation Stage incubator (T) + objective heater
links
  • [ beam path]
  • [ advanced system check]
inv.nr. MOZG040809900



Personal tools