MZ2 - Zeiss 2photon inverted
From BioDIP
(Difference between revisions)
(13 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
{{Equipment | {{Equipment | ||
− | |system-number=MPI-MZ2 | + | |system-number=MPI- MZ2 |
|system-name=MZ2 Zeiss 2-photon inverted | |system-name=MZ2 Zeiss 2-photon inverted | ||
|type=Microscope | |type=Microscope | ||
Line 6: | Line 6: | ||
|facility=MPI-CBG LMF | |facility=MPI-CBG LMF | ||
|building=MPI-CBG | |building=MPI-CBG | ||
− | |room= | + | |room=456A |
− | |description=Zeiss LSM 710 NLO | + | |Facility-logo=MPI-CBG-Lmf-logo-big.png |
− | + | |Institute-logo=Logo MPI-CBG.jpg | |
− | + | |description=Zeiss LSM 710 NLO<br>Multiphoton Laser Scanning Microscope with a tunable pulsed infra-red laser (Chameleon Vision II) for multi-photon excitation.<br>Single photon point scanning confocal system with three PMTs (one spectral) and transmitted light detector. Motorized stage for multi-point acquisition | |
|applications=imaging of thick specimens fast bleaching samples. Spectral imaging, routine dye combinations, tile scan, multi position scan. | |applications=imaging of thick specimens fast bleaching samples. Spectral imaging, routine dye combinations, tile scan, multi position scan. | ||
− | |image= | + | |image=MZ2 - Zeiss 2photon inverted.jpg |
|stand-name=Zeiss - Axio Observer | |stand-name=Zeiss - Axio Observer | ||
|stand=Inverted | |stand=Inverted | ||
|microscope=motorized XY stage, motorized Z-drive, | |microscope=motorized XY stage, motorized Z-drive, | ||
− | |obj1=Zeiss | + | |obj1=Zeiss Plan-Apochromat 10x 0.45 |
|obj2=Zeiss C-Apochromat 40x 1.2 W | |obj2=Zeiss C-Apochromat 40x 1.2 W | ||
+ | |obj3=Zeiss Plan-Apochromat 20x 0.8 | ||
+ | |obj4=Zeiss Plan-Apochromat 63x 1.4 Oil | ||
+ | |obj5=Zeiss LD C-Apochromat 40x 1.1 W | ||
+ | |obj6=Zeiss LD LCI Plan-Apochromat 25x 0.8 Oil/Glyc/Water DIC | ||
+ | |obj7=Zeiss LCI Plan-Neofluar 63x 1.3 Gly/Water DIC | ||
|ill1=Fluorescence (Metal Halide, PRIOR, 200W) | |ill1=Fluorescence (Metal Halide, PRIOR, 200W) | ||
|ill2=Transmitted Light (Halogen) | |ill2=Transmitted Light (Halogen) | ||
Line 29: | Line 34: | ||
|reflectors=- | |reflectors=- | ||
|features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan | |features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan | ||
− | |software=ZEN | + | |software=ZEN 2010 |
|incubation=Not available | |incubation=Not available | ||
− | |inv=AIM-System 2501000455 | + | |link1=https://docs.google.com/spreadsheet/pub?key=0AiAvGnTuH4LedFpzYnAwV19RWlJjQVFoa2VwR0dEX0E&output=html |
+ | |inv=AIM-System 2501000455 10.1.30.42 | ||
}} | }} |
Latest revision as of 19:20, 3 February 2016
[edit] Directions
[edit] Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
[edit] Details
microscope | Zeiss - Axio Observer, Inverted stand, motorized XY stage, motorized Z-drive, | ||
objectives | |||
illumination | |||
detection | [[detection::Single photon detection: 2 confocal PMTs, QUASAR detector with 32 channels, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral prism sliders for emission detection range selection, common pinhole changeable for each detector setting 2 photon detection: 2 non-descanned detectors (NDD) - NDD-dichromatic mirrors and emission filters]] | ||
reflectors | - | ||
features | simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan | ||
software | ZEN 2010 | ||
incubation | Not available | ||
links |
| ||
inv.nr. | AIM-System 2501000455 10.1.30.42 |