MZ2 - Zeiss 2photon inverted

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 9: Line 9:
 
|Facility-logo=MPI-CBG-Lmf-logo-big.png
 
|Facility-logo=MPI-CBG-Lmf-logo-big.png
 
|Institute-logo=Logo MPI-CBG.jpg
 
|Institute-logo=Logo MPI-CBG.jpg
|description=Zeiss LSM 710 NLO<br>Multiphoton Laser Scanning Microscope with a tunable pulsed infra-red laser (Chameleon Vision II) for multi-photon excitation.  
+
|description=Zeiss LSM 710 NLO<br>Multiphoton Laser Scanning Microscope with a tunable pulsed infra-red laser (Chameleon Vision II) for multi-photon excitation.<br>
<br>Single photon point scanning confocal system with three PMTs (one spectral) and transmitted light detector. Motorized stage for multi-point acquisition
+
Single photon point scanning confocal system with three PMTs (one spectral) and transmitted light detector. Motorized stage for multi-point acquisition
 
|applications=imaging of thick specimens fast bleaching samples. Spectral imaging, routine dye combinations, tile scan, multi position scan.
 
|applications=imaging of thick specimens fast bleaching samples. Spectral imaging, routine dye combinations, tile scan, multi position scan.
 
|image=MZ2 - Zeiss 2photon inverted.jpg
 
|image=MZ2 - Zeiss 2photon inverted.jpg

Revision as of 19:20, 3 February 2016

Single photon point scanning confocal system with three PMTs (one spectral) and transmitted light detector. Motorized stage for multi-point acquisition"Zeiss LSM 710 NLO<br />Multiphoton Laser Scanning Microscope with a tunable pulsed infra-red laser (Chameleon Vision II) for multi-photon excitation.<br /> Single photon point scanning confocal system with three PMTs (one spectral) and transmitted light detector. Motorized stage for multi-point acquisition" cannot be used as a page name in this wiki.

Suitable for imaging of thick specimens fast bleaching samples. Spectral imaging, routine dye combinations, tile scan, multi position scan..
MZ2 - Zeiss 2photon inverted.jpg


Directions

Logo MPI-CBG.jpg
MPI-CBG-Lmf-logo-big.pngMPI-CBG LMF (MPI-CBG, 456A)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope Zeiss - Axio Observer, Inverted stand, motorized XY stage, motorized Z-drive,
objectives
Zeiss Plan-Apochromat 10x 0.45
Zeiss C-Apochromat 40x 1.2 W
Zeiss Plan-Apochromat 20x 0.8
Zeiss Plan-Apochromat 63x 1.4 Oil
Zeiss LD C-Apochromat 40x 1.1 W
Zeiss LD LCI Plan-Apochromat 25x 0.8 Oil/Glyc/Water DIC
Zeiss LCI Plan-Neofluar 63x 1.3 Gly/Water DIC
illumination
Fluorescence (Metal Halide, PRIOR, 200W)
Transmitted Light (Halogen)
Laser Diode 405 nm
Laser Argon Multiline 458, 477, 488, 514 nm
Laser DPSS 561 nm
Laser HeNe 594 nm
Laser HeNe 633 nm
Laser Multiphoton Chameleon 700-1064 nm
detection [[detection::Single photon detection: 2 confocal PMTs, QUASAR detector with 32 channels, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral prism sliders for emission detection range selection, common pinhole changeable for each detector setting

2 photon detection: 2 non-descanned detectors (NDD) - NDD-dichromatic mirrors and emission filters]]