This manual gives some hints about the usage of the Warner heating and cooling incubation system.
 
  
 
The TB-3 is available in two versions:
 
The TB-3 is available in two versions:
 
*[http://www.warneronline.com/product_info.cfm?id=1314 CCD] - made for 35 mm dishes and Warner RC-40 chambers
 
*[http://www.warneronline.com/product_info.cfm?id=1314 CCD] - made for 35 mm dishes and Warner RC-40 chambers
 
*[http://www.warneronline.com/product_info.cfm?id=1315 CS] - made for chamber slides up to 1 x 3'
 
*[http://www.warneronline.com/product_info.cfm?id=1315 CS] - made for chamber slides up to 1 x 3'
 +
 +
One main advantage of the Warner heating and cooling incubation system is the cooling of small volumes of medium directly on the microscope. Due to the design (water-cooled Peltier element) it is quite light-weight and works on fragile Z-stages as well. The official working range is 5 - 50 ° celsius. However, real 5 °C could never be reached on our side. In best case we got it down to 6,5 °C.
 +
 +
This manual gives some hints about its usage.
  
 
== Requirements ==
 
== Requirements ==
Line 11: Line 13:
 
*Warner Instruments TB-3 CCD Thermal Insert
 
*Warner Instruments TB-3 CCD Thermal Insert
 
*Prior NZ200CE NanoScan Z-stage - or different/custom-made insert for other stages
 
*Prior NZ200CE NanoScan Z-stage - or different/custom-made insert for other stages
 +
*OKO-LAB glass-bottom metal dish, model [http://www.oko-lab.com/local/repository/501.pdf RA-35-18-2000-06] (recommended for best performance)
  
 
== Manual ==
 
== Manual ==

Revision as of 16:06, 28 August 2008

Overview

The TB-3 is available in two versions:

  • CCD - made for 35 mm dishes and Warner RC-40 chambers
  • CS - made for chamber slides up to 1 x 3'

One main advantage of the Warner heating and cooling incubation system is the cooling of small volumes of medium directly on the microscope. Due to the design (water-cooled Peltier element) it is quite light-weight and works on fragile Z-stages as well. The official working range is 5 - 50 ° celsius. However, real 5 °C could never be reached on our side. In best case we got it down to 6,5 °C.

This manual gives some hints about its usage.

Requirements

  • Warner Instruments TB-3 CCD Thermal Insert
  • Prior NZ200CE NanoScan Z-stage - or different/custom-made insert for other stages
  • OKO-LAB glass-bottom metal dish, model RA-35-18-2000-06 (recommended for best performance)