H2 - Nikon STORM - TIRF
From BioDIP
(Difference between revisions)
Line 14: | Line 14: | ||
|stand-name=Nikon - Eclipse Ti | |stand-name=Nikon - Eclipse Ti | ||
|stand=Inverted | |stand=Inverted | ||
− | |microscope=motorized stage; double-floor with two reflector-revolvers; manual 1.5x zoom lens; motorized TIRF-condenser with additional manual collimating lens | + | |microscope=motorized stage; double-floor with two reflector-revolvers; manual 1.5x zoom lens;<br>motorized TIRF-condenser with additional manual collimating lens |
|obj1=Nikon PlanApo 10x/0.45 DIC 0.17 | |obj1=Nikon PlanApo 10x/0.45 DIC 0.17 | ||
|obj2=Nikon PlanApo 60x/1.2 WI 0.15-0.18 | |obj2=Nikon PlanApo 60x/1.2 WI 0.15-0.18 | ||
Line 25: | Line 25: | ||
|ill4=Laser DPSS 561 nm | |ill4=Laser DPSS 561 nm | ||
|ill5=Laser DPSS 640 nm | |ill5=Laser DPSS 640 nm | ||
− | |detection=at left camera port: Andor iXon EM+ DU-897 BV back-illuminated EM-CCD with cylindrical lens; dexel size of camera chip: 16um | + | |detection=at left camera port: Andor iXon EM+ DU-897 BV back-illuminated EM-CCD with cylindrical lens; dexel size of camera chip: 16um<br>at right camera port: Andor iXon3 DU-897 BV back-illuminated EM-CCD with 10 position filter wheel and Hamamtsu W-View image splitter; dexel size of camera chip: 16um |
− | at right camera port: Andor iXon3 DU-897 BV back-illuminated EM-CCD with 10 position filter wheel and Hamamtsu W-View image splitter; dexel size of camera chip: 16um | + | |reflectors=Sutter filter wheel:<br>position 0: BrightLine 617/73, 1: Razor Edge LP488RS, 2: Razor Edge LP664RS, 3: BrightLine 447/60, 4: open, 5: Dual BrightLine 512/630 (512/23 + 630/91), 6: BrightLine 628/40, 7: BrightLine 525/30, 8: BrightLine 607/36, 9: BrightLine 520/15 |
− | |reflectors=Sutter filter wheel: | + | |
− | position 0: BrightLine 617/73, 1: Razor Edge LP488RS, 2: Razor Edge LP664RS, 3: BrightLine 447/60, 4: open, 5: Dual BrightLine 512/630 (512/23 + 630/91), 6: BrightLine 628/40, 7: BrightLine 525/30, 8: BrightLine 607/36, 9: BrightLine 520/15 | + | |
Hamamatsu W-View image splitter: | Hamamatsu W-View image splitter: |
Revision as of 14:28, 13 May 2014
Directions
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | Nikon - Eclipse Ti, Inverted stand, motorized stage; double-floor with two reflector-revolvers; manual 1.5x zoom lens; motorized TIRF-condenser with additional manual collimating lens"motorized stage; double-floor with two reflector-revolvers; manual 1.5x zoom lens;<br />motorized TIRF-condenser with additional manual collimating lens" cannot be used as a page name in this wiki. | ||
objectives | |||
illumination | |||
detection | at left camera port: Andor iXon EM+ DU-897 BV back-illuminated EM-CCD with cylindrical lens; dexel size of camera chip: 16um at right camera port: Andor iXon3 DU-897 BV back-illuminated EM-CCD with 10 position filter wheel and Hamamtsu W-View image splitter; dexel size of camera chip: 16um | ||
reflectors | Sutter filter wheel: position 0: BrightLine 617/73, 1: Razor Edge LP488RS, 2: Razor Edge LP664RS, 3: BrightLine 447/60, 4: open, 5: Dual BrightLine 512/630 (512/23 + 630/91), 6: BrightLine 628/40, 7: BrightLine 525/30, 8: BrightLine 607/36, 9: BrightLine 520/15 Hamamatsu W-View image splitter: | ||
features | - | ||
software | NIS Elements with N-STORM module | ||
incubation | Cage incubator (T+CO2) | ||
links |
| ||