Applications
|
Long-term observation of living cells, Fast multi-fluorescence 3-D time-lapse, Fast and precise image acquisition and analysis, robust automated object detection and cell separation, visual correlation of cell images and analysis results. +
|
Building
|
MPI-CBG +
|
Description
|
Motorized inverted wide-field system with temperature and CO2 cage incubator. +
|
Detection
|
Hamamatsu Camera ORCA ER, progressive scan … Hamamatsu Camera ORCA ER, progressive scan interline CCD, 1344 x 1024 pixels, 6.45 um pixel size, 14.75 MHz digitization, 8 e- rms readout noise, 8 fps @ full frame, 18.000 e- full well capacity, 2250:1 dynamic range, peltier cooling (-20 degrees C @ 20 degrees C ambient), 12 bit ADC, 0.1 electron/pixel/sec dark current, up to 10x analog gain, offset functionst, up to 10x analog gain, offset functions
|
Facility
|
MPI-CBG LMF +
|
Id
|
MPI-L5 +
|
Ill
|
Transmitted Light (Halogen) +
, Fluorescence (Xenon) +
|
Image
|
L5 - Olympus ScanR CellR.jpg +
|
Incubation
|
Cage incubator (T+CO2) +
|
Invno
|
405679 10.1.145.24 +
|
Name
|
Olympus ScanR+CellR +
|
Obj
|
Olympus UPlan-SApochromat 40x 0.9 +
, Olympus UPlan-SApochromat 20x 0.75 +
, Olympus UPlan-SApochromat 10x 0.4 +
, Olympus UPlan-FluarN 20x 0.5 Ph1 +
, Olympus LCPlan-Fluar 20x 0.4 Ph1 +
, Olympus UPlan-FluarN 40x 0.75 Ph2 +
, Olympus UPlan-SApochromat 4x 0.16 +
, Olympus Uplan-Apochromat 40x 1 Oil +
, Olympus UPlan-SApochromat 60x 1.35 Oil +
, Olympus UPlan-Fluar 20x 0.5 +
|
Reflectors
|
MT20 Excitation Unit<br /> <br /& … MT20 Excitation Unit<br /> <br /> - EXCITATION FILTERS <br /> 387 / 403 / 485 / 492 / 560 / 572/ 650 <br /> <br />
- DICHROICS AND EMISSION FILTERS <br /> <br /> * POSITION 1: <br /> D 405-435/450-485/510-550/590-675 <br />M 450-475/515-545/600-665 <br /> <br /> * POSITION 2:<br /> D QBP 410-465, 504-538, 581-632, 669-743 <br /> M QBP 415-461, 507-533, 586-625, 673-722 <br /> <br /> * POSITION 3: EMPTY <br /> <br /> * POSITION 4: EMPTY<br /> <br /> * POSITION 5:<br /> D 485-570/605-690<br /> M 500-560/615-675<br /> <br /> * POSITION 6<br /> D 440-490/510-575/610-675 <br />M 450-480/525-560/615-660-675 <br />M 450-480/525-560/615-660
|
Room
|
U50 +
|
Software
|
- +
|
Stand
|
Inverted +
|
Stand-details
|
Motorized XY stage, motorized Z-drive, fluorescence, transmitted light +
|
Stand-name
|
Olympus - IX81 +
|
System type
|
Wide-Field +
|
Type
|
Not listed +
|
Has queryThis property is a special property in this wiki.
|
L5 - Olympus ScanR+CellR +
|
Has improper value forThis property is a special property in this wiki.
|
Description +
, Features +
|
Categories |
Wide-Field +
, MPI-CBG LMF +
, Not listed +
|
Modification dateThis property is a special property in this wiki.
|
3 February 2016 14:30:31 +
|
PageThis property is a special property in this wiki.
|
L5 - Olympus ScanR+CellR +
|