Browse wiki

From BioDIP
Jump to: navigation, search
ApoTome2, inverse, CRTD
Applications Multichannel fluorescence, 3-D, time-lapse, tile scan, multiple points, hardware autofocus +
Building CRTD  +
Description Our inverted ApoTome2 Microscope with hardware autofocus, colour and monochrome cameras is designed for routine work on fixed sample. Optical sectioning can be obtained on fixed samples by the use of the ApoTome2 slider. +
Detection Axiocam HRc (1388*1040, 6,45*6,45µm pixel) - color <br /> Axiocam MRm (1388*1040, 6,45*6,45µm pixel) - b/w <br /> tube lens 1x and 1.6x
Facility Imaging@BIOTEC/CRTD +
Features - +
Id BIO04 +
Ill Fluorescence (Metal Halide, HXP, 120W) + , Transmitted Light (Halogen) + , Fluorescence (LED, 470nm) + , Fluorescence (LED, 590nm) +
Image ApoTome2, inverse, CRTD.jpg +
Incubation Not available +
Invno 70836 +
Name ApoTome2, inverse, CRTD +
Obj Zeiss EC Plan-Neofluar 10x 0.3 Ph1 + , Zeiss EC Plan-Neofluar 40x 0.6 Ph2 + , Zeiss C-Apochromat 63x 1.2 W + , Zeiss EC Plan Neofluar 2.5x 0.075 + , Zeiss LD Achroplan 20x 0.4 Ph2 + , Zeiss Plan-Apochromat 20x 0.8 +
Reflectors FS 49: EX BP 347/55; BS 395; EM BP 445/50FS 49: EX BP 347/55; BS 395; EM BP 445/50 (Dapi)<br /> FS 38HE: EX BP 471/40 (HE); BS 495 (HE); EM BP 495-545 (HE); (GFP)<br /> FS 43HE: EX BP 550/25 (HE); BS 570 (HE); EM 605/70 (HE); (Cy3)<br /> FS Cy5: EX BP 662-738; BS 660; EM BP 700/75; (Cy5)<br /> FS F56-422: EX BP 474/23 & BP 585/29; BS 495-555 & BP 610-690; EM BP 525/55 & BP 645/60; (GFP-DsRed)<br /> FS Analysator for DIC and Transmissiongt; FS Analysator for DIC and Transmission
Room -1.124 +
Stand Inverted +
Stand-details Automatic XY stage, motorized z-stage, fluorescence, transmitted light with manual DIC (Senarmont), b/w epifluorescence acquisition, Optical Sectioning (ApoTome2), Mosaic (tile scans) +
Stand-name Zeiss - Axio Observer.Z1 +
System type Structured Illumination +
Type Microscope +
Has queryThis property is a special property in this wiki. ApoTome2, inverse, CRTD +
Has improper value forThis property is a special property in this wiki. Description  + , Software  +
Categories Microscope  + , Imaging@BIOTEC/CRTD  + , Structured Illumination  +
Modification dateThis property is a special property in this wiki. 17 October 2014 11:36:09  +
PageThis property is a special property in this wiki. ApoTome2, inverse, CRTD +
hide properties that link here 
ApoTome2, inverse, CRTD + Name
ApoTome2, CRTD + redirect page
ApoTome2, inverse, CRTD + PageThis property is a special property in this wiki.
 

 

Enter the name of the page to start browsing from.
Views