(previous 25) (next 25)A | |
---|---|
ApoTome, 2nd floor, MTZ + | Axiocam MRm (1388*1040, 6,45*6,45µm) - b/w Axiocam MRc (1388*1040 pixel, 6,45*6,45µm) - color |
ApoTome1 2nd floor, inv., CRTD + | Axiocam MRm (1388*1040, 6,45*6,45µm) - b/w |
ApoTome1 3rd floor, upr., CRTD + | Axiocam MRm (1388*1040, 6,45*6,45µm) - b/w<br /> Axiocam MRc (1388*1040 pixel, 6,45*6,45µm) - color |
ApoTome1, inverse, BIOTEC + | Axiocam MRm (1388*1040, 6,45*6,45µm pixel) - b/w<br /> Axiocam MRc (1388*1040, 6,45*6,45µm pixel) - color |
ApoTome2, inverse, CRTD + | Axiocam HRc (1388*1040, 6,45*6,45µm pixel) - color <br /> Axiocam MRm (1388*1040, 6,45*6,45µm pixel) - b/w <br /> tube lens 1x and 1.6x |
Axioscan slide scanner + | Orca Flash 4.0 V2 , 2048x2048 (4 Mega Pixel), 6.5x6.5 um pixel size, 1" chip size |
C | |
CL1 - Leica TCS SP2 + | point scanner, 3 confocal PMTs, T-PMT, prism and sliders for spectral detection range selection, central pinhole |
CZ1 - Zeiss LSM Meta + | point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector |
CZ2 - Zeiss LSM UV + | point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector |
CZ3 - Zeiss LSM 405/594 + | point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector |
CZ4 - Zeiss LSM DuoScan + | point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector |
CZ5 - Zeiss LSM 700 inverted + | 2 PMTs<br /> No transmission detector |
CZ6 - Zeiss LSM 880 Airy inverted + | 32 GaAsP PMT channels <br /> 2 PMTs<br /> 1 32-channel Airy Scan detector <br /> transmission detector |
CZ7 - Zeiss LSM 880 Airy upright + | 32 GaAsP PMT channels <br /> 2 PMTs<br /> 1 32-channel Airy Scan detector <br /> transmission detector |
D | |
D1 - SPIM Demo + | Zeiss CCD Axiocam camera. Max 3fps full chip. Faster with binning. |
Deleted - BIO25 + | - |
G | |
Grid LSM & WF, upr., BIOTEC + | dual ccd configuration: Coolsnap ES for widefield fluorescence AND <br /> Cascade II EMCCD for confocal sectioning (multi point illumination, variable pinhole size), dual channel emission beamsplitter |
H | |
H1 - DeltaVision OMX - pDV + | 4x sCMOS cooled to 3oC. Simultaneous or sequential imaging. |
H2 - Nikon STORM - TIRF + | at left camera port: Andor iXon EM+ DU-897 BV back-illuminated EM-CCD SN #4431 with cylindrical lens; dexel size of camera chip: 16um<br />at right camera port: Andor iXon3 DU-897 BV back-illuminated EM-CCD # 6499 with 10 position filter wheel and Hamamtsu W-View image splitter; dexel size of camera chip: 16um |
L | |
L1 - Long Term Timelapse I + | Princeton Instruments monochrome CCD 1024x1024 pixels (6.7 um²) |
L2 - Long Term Timelapse II + | Roper Scientific CoolSNAP ES, monochromatic Sony ICX285AL chip, 1392 x 1040 pixels, 6.45 μm pixel size, 20 MHz digitization, 8 e- rms readout noise @ 20 MHz, thermoelectric cooling (5°C below ambient temperature) |
L4 - Long Term Time Lapse Oates Andor + | iXon DU-888E-COO#BV X-4631 |
L5 - Olympus ScanR+CellR + | Hamamatsu Camera ORCA ER, progressive scan interline CCD, 1344 x 1024 pixels, 6.45 um pixel size, 14.75 MHz digitization, 8 e- rms readout noise, 8 fps @ full frame, 18.000 e- full well capacity, 2250:1 dynamic range, peltier cooling (-20 degrees C @ 20 degrees C ambient), 12 bit ADC, 0.1 electron/pixel/sec dark current, up to 10x analog gain, offset functions |
LSI Macro Confocal, CRTD + | 1 spectral detector (PMT) |
LSM 510, inverse, BIOTEC + | point scanner, 2 confocal PMTs, 1 META detector, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector |