Property:Detection
From BioDIP
This is a property of type Text.
Pages using the property "Detection"
Showing 25 pages using this property.
(previous 25) (next 25)L | |
---|---|
LSM 700, inverse, BIOTEC + | 2 PMTs<br /> 1 transmission detector |
LSM 780, upright, CRTD + | 32 PMT channels (GaAsP)<br /> 2 PMTs<br /> 1 Airyscan (GaAsP)<br /> transmission detector PMT |
LSM 780/FCS, inverse, BIOTEC + | 32 PMT channels (GaAsP)<br /> 2 PMTs<br /> transmission detector<br /> 2 APDs (Confocor 3) |
LSM 780/FLIM, inverse, CRTD + | 32 PMT channels (GaAsP) <br /> 2 PMTs <br /> transmission detector |
LZ1 - Zeiss Lightsheet Z.1 + | Two sCMOS cameras; pixel size: 6.5 µm |
LZ2 - Zeiss Lightsheet Z.1 + | Two sCMOS cameras; pixel size: 6.5 µm |
Live Cell 4D, BIOTEC + | CCD Coolsnap HQ (1392*1040, 6,45*6,45µm pixel) |
Live Cell AF6000, CRTD + | CCD Leica DFC 350 FX R2 (1392*1040, 6,45*6,45µm pixel)<br /> Photometrics Cascade (512*512, 16*16µm pixel) |
Live Cell/TIRF AF6000, BIOTEC + | Andor iXON 897 EMCCD (512*512, 16µm pixels), Leica DFC (1392*1040, 6,45µm pixels), reflectors for fluorescence and TIRF, external emission filter wheel for rapid acquisition with Andor EMCCD |
M | |
MB1 - BioRad 2photon + | 2 non-descanned PMTs<br />2 confocal PMTs |
ML1 - Leica 2photon in-vivo + | Confocal: spectral detector with five detectors: four hybrid detectors and one PMT<br /> Multiphoton: four non-descanned detectors: two hybrid detectors and two PMTs |
MPI-TDS1 + | - 3x CCD cameras with 1.3 mega pixel – peltier-cooled – 12 bit resolution |
MPI-TDS3 + | - CCD camera with ?? mega pixel, Peltier-cooled, 12 bit resolution |
MPI20 - Olympus Worm LTTL + | - |
MTZ01 - Zeiss LSM 510 + | point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector |
MTZ02 - Leica TCS SP5 + | point scanner, 3 confocal PMTs, T-PMT, AOBS for excitation/emission splitting, prism and spectral sliders for detection range selection, central pinhole<br />optional wide-field detection via color camera, CCD Leica DFC 500 (1360x1024 up to 4080x3072, 6.45x6.45µm pixel) |
MZ1 - Zeiss 2photon upright + | '''Single photon detection:''' 2 confocal PMTs with enhanced detection in the red range, GaAsP spectral detector with 32 channels, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral prism sliders for emission detection range selection, common pinhole changeable for each detector setting <br /> '''2 photon detection:''' 4 non-descanned GaAsP detectors (2 BiG units) in reflected direction, 2 non-descanned PMTs (1 NDD moule) in transmitted direction |
O | |
Olympus Spinning disc + | camera: iXon Ultra 897<br /> - 512x512 @ 56 fps<br /> - back illuminated imaging EMCCD |
P | |
Perkin Elmer Operetta + | - CCD camera with 1.3 mega pixel, Peltier-cooled, 14 bit resolution |
S | |
SD3 - Zeiss Spinning Disc + | Spinning disc scan head Yokogawa CSU-X1 with two camera ports; pinhole radius: 25um, pinhole spacing: 250um; 3 DCs: (1) RTFT 405+488+561; (2) RQFT 405+488+568+647; (3) RTFT 457+514+647 Zeiss AxiCam MRm with EM filter wheel: (1) BP 450/50, (2) 458LP, (3) DBP 527/54 + 645/60, (4) 535/30, (5) 629/62, (6) BP 690/50; Roper evolve 515 EMCCD with manual EM filter holder |
SD4 - Andor Revolution WD Borealis Mosaic + | Spinning disc scan head Yokogawa CSU-W1 (4000rpm) with two pinhole discs (50um and 25um) and simultaneous dual camera detection: Camera 1 (Master): Andor iXon 888 Ultra with fringe suppression; Camera 2 (Slave): Andor iXon 888 Ultra |
SE1 -Bachhoffer Chamber I + | - |
SP5 I, upright, BIOTEC + | point scanner, 2 confocal HyD´s, 3 confocal PMTs, T-PMT, AOBS for excitation/emission splitting, SP detector for detection range selection, common pinhole |
SP5 II, upright, CRTD + | point scanner, 5 confocal PMTs, T-PMT, AOBS for excitation/emission splitting, SP detector for detection range selection, common pinhole |
SP5 MP, inverse, CRTD + | point scanner and resonnant scanner, 2 confocal HyD´s, 3 confocal PMTs, T-PMT, AOBS for excitation/emission splitting, SP detector for detection range selection, common pinhole<br />Non Descan Detector for Multi Photon Imaging : FITC (525/50), TRITC (610/70) |